2022-04-15 11:49:24 +00:00
|
|
|
#!/usr/bin/env bash
|
|
|
|
NEXTID=$(pvesh get /cluster/nextid)
|
|
|
|
INTEGER='^[0-9]+$'
|
|
|
|
YW=`echo "\033[33m"`
|
|
|
|
BL=`echo "\033[36m"`
|
|
|
|
RD=`echo "\033[01;31m"`
|
|
|
|
CM='\xE2\x9C\x94\033'
|
|
|
|
BGN=`echo "\033[4;92m"`
|
|
|
|
GN=`echo "\033[32m"`
|
|
|
|
CL=`echo "\033[m"`
|
|
|
|
APP="Zigbee2MQTT"
|
|
|
|
NSAPP=$(echo ${APP,,} | tr -d ' ')
|
2022-04-15 12:24:27 +00:00
|
|
|
|
2022-04-15 11:49:24 +00:00
|
|
|
while true; do
|
|
|
|
read -p "This will create a New ${APP} LXC. Proceed(y/n)?" yn
|
|
|
|
case $yn in
|
|
|
|
[Yy]* ) break;;
|
|
|
|
[Nn]* ) exit;;
|
|
|
|
* ) echo "Please answer yes or no.";;
|
|
|
|
esac
|
|
|
|
done
|
|
|
|
clear
|
|
|
|
function header_info {
|
|
|
|
echo -e "${YW}
|
|
|
|
_______ _ ___ __ __ ____ _______ _______
|
|
|
|
|___ (_) | | |__ \| \/ |/ __ \__ __|__ __|
|
|
|
|
/ / _ __ _| |__ ___ ___ ) | \ / | | | | | | | |
|
|
|
|
/ / | |/ _ | _ \ / _ \/ _ \ / /| |\/| | | | | | | | |
|
|
|
|
/ /__| | (_| | |_) | __/ __// /_| | | | |__| | | | | |
|
|
|
|
/_____|_|\__, |____/ \___|\___|____|_| |_|\___\_\ |_| |_|
|
|
|
|
v3 __/ |
|
|
|
|
|___/
|
|
|
|
${CL}"
|
|
|
|
}
|
|
|
|
|
|
|
|
header_info
|
|
|
|
function pve_check() {
|
2022-04-15 12:24:27 +00:00
|
|
|
PVE=$(pveversion | grep "pve-manager/7" | wc -l)
|
2022-04-15 11:49:24 +00:00
|
|
|
if [[ $PVE != 1 ]]; then
|
|
|
|
echo -e "${RD}This script requires Proxmox Virtual Environment 7.0 or greater"
|
|
|
|
echo -e "Exiting..."
|
|
|
|
sleep 2
|
|
|
|
exit
|
|
|
|
fi
|
|
|
|
}
|
|
|
|
|
|
|
|
function default_settings() {
|
|
|
|
clear
|
|
|
|
header_info
|
|
|
|
echo -e "${BL}Using Default Settings${CL}"
|
2022-04-15 12:11:50 +00:00
|
|
|
echo -e "${GN}Using CT Type ${BGN}Privileged${CL}"
|
|
|
|
CT_TYPE="0"
|
2022-04-15 11:49:24 +00:00
|
|
|
echo -e "${GN}Using CT Password ${BGN}Automatic Login${CL}"
|
|
|
|
PW=" "
|
|
|
|
echo -e "${GN}Using ID ${BGN}$NEXTID${CL}"
|
|
|
|
CT_ID=$NEXTID
|
|
|
|
echo -e "${GN}Using CT Name ${BGN}$NSAPP${CL}"
|
|
|
|
HN=$NSAPP
|
|
|
|
echo -e "${GN}Using Disk Size ${BGN}4GB${CL}"
|
|
|
|
SIZEDISK="4"
|
|
|
|
echo -e "${GN}Using Storage ${BGN}local-lvm${CL}"
|
|
|
|
STORAGETYPE="local-lvm"
|
|
|
|
echo -e "${GN}Using ${BGN}2vCPU${CL}"
|
|
|
|
CORE_COUNT="2"
|
|
|
|
echo -e "${GN}Using ${BGN}1024MiB${CL}${GN} RAM${CL}"
|
|
|
|
RAM_SIZE="1024"
|
|
|
|
echo -e "${GN}Using IP Address ${BGN}DHCP${CL}"
|
|
|
|
NET=dhcp
|
|
|
|
echo -e "${GN}Using VLAN Tag ${BGN}NONE${CL}"
|
|
|
|
VLAN=" "
|
|
|
|
}
|
|
|
|
|
|
|
|
function advanced_settings() {
|
|
|
|
clear
|
|
|
|
header_info
|
|
|
|
echo -e "${RD}Using Advanced Settings${CL}"
|
2022-04-15 12:18:00 +00:00
|
|
|
echo -e "${YW}Type Unprivileged, or Press [ENTER] for Default: Privileged "
|
2022-04-15 11:49:24 +00:00
|
|
|
read CT_TYPE1
|
2022-04-15 12:32:34 +00:00
|
|
|
if [ -z $CT_TYPE1 ]; then CT_TYPE1="Privileged"
|
|
|
|
CT_TYPE="0"
|
2022-04-15 11:49:24 +00:00
|
|
|
echo -en "${GN}Set CT Type ${BL}$CT_TYPE1${CL}"
|
|
|
|
else
|
2022-04-15 12:11:50 +00:00
|
|
|
CT_TYPE1="Unprivileged"
|
|
|
|
CT_TYPE="1"
|
2022-04-15 12:32:34 +00:00
|
|
|
echo -en "${GN}Set CT Type ${BL}Unprivileged${CL} ${RD}NO DEVICE PASSTHROUGH${CL}"
|
2022-04-15 11:49:24 +00:00
|
|
|
fi;
|
|
|
|
echo -e " ${CM}${CL} \r"
|
|
|
|
sleep 1
|
|
|
|
clear
|
|
|
|
header_info
|
|
|
|
echo -e "${RD}Using Advanced Settings${CL}"
|
|
|
|
echo -e "${GN}Using CT Type ${BGN}$CT_TYPE1${CL}"
|
|
|
|
echo -e "${YW}Set Password, or Press [ENTER] for Default: Automatic Login "
|
|
|
|
read PW1
|
|
|
|
if [ -z $PW1 ]; then PW1="Automatic Login" PW=" ";
|
|
|
|
echo -en "${GN}Set CT ${BL}$PW1${CL}"
|
|
|
|
else
|
|
|
|
PW="-password $PW1"
|
|
|
|
echo -en "${GN}Set CT Password ${BL}$PW1${CL}"
|
|
|
|
|
|
|
|
fi;
|
|
|
|
echo -e " ${CM}${CL} \r"
|
|
|
|
sleep 1
|
|
|
|
clear
|
|
|
|
header_info
|
|
|
|
echo -e "${RD}Using Advanced Settings${CL}"
|
|
|
|
echo -e "${GN}Using CT Type ${BGN}$CT_TYPE1${CL}"
|
|
|
|
echo -e "${GN}Using CT Password ${BGN}$PW1${CL}"
|
|
|
|
echo -e "${YW}Enter the CT ID, or Press [ENTER] to automatically generate (${NEXTID}) "
|
|
|
|
read CT_ID
|
|
|
|
if [ -z $CT_ID ]; then CT_ID=$NEXTID; fi;
|
|
|
|
echo -en "${GN}Set CT ID To ${BL}$CT_ID${CL}"
|
|
|
|
echo -e " ${CM}${CL} \r"
|
|
|
|
sleep 1
|
|
|
|
clear
|
|
|
|
header_info
|
|
|
|
echo -e "${RD}Using Advanced Settings${CL}"
|
|
|
|
echo -e "${GN}Using CT Type ${BGN}$CT_TYPE1${CL}"
|
|
|
|
echo -e "${GN}Using CT Password ${BGN}$PW1${CL}"
|
|
|
|
echo -e "${GN}Using ID ${BGN}$CT_ID${CL}"
|
|
|
|
echo -e "${YW}Enter CT Name (no-spaces), or Press [ENTER] for Default: $NSAPP "
|
|
|
|
read CT_NAME
|
|
|
|
if [ -z $CT_NAME ]; then
|
|
|
|
HN=$NSAPP
|
|
|
|
else
|
|
|
|
HN=$(echo ${CT_NAME,,} | tr -d ' ')
|
|
|
|
fi
|
|
|
|
echo -en "${GN}Set CT Name To ${BL}$HN${CL}"
|
|
|
|
echo -e " ${CM}${CL} \r"
|
|
|
|
sleep 1
|
|
|
|
clear
|
|
|
|
header_info
|
|
|
|
echo -e "${RD}Using Advanced Settings${CL}"
|
|
|
|
echo -e "${GN}Using CT Type ${BGN}$CT_TYPE1${CL}"
|
|
|
|
echo -e "${GN}Using CT Password ${BGN}$PW1${CL}"
|
|
|
|
echo -e "${GN}Using ID ${BGN}$CT_ID${CL}"
|
|
|
|
echo -e "${GN}Using CT Name ${BGN}$HN${CL}"
|
|
|
|
echo -e "${YW}Enter a Disk Size, or Press [ENTER] for Default: 4Gb "
|
|
|
|
read SIZEDISK
|
|
|
|
if [ -z $SIZEDISK ]; then SIZEDISK="4"; fi;
|
|
|
|
if ! [[ $SIZEDISK =~ $INTEGER ]] ; then echo "ERROR! SIZEDISK MUST HAVE INTEGER NUMBER!"; exit; fi;
|
|
|
|
echo -en "${GN}Set Disk Size To ${BL}$SIZEDISK${CL}"
|
|
|
|
echo -e " ${CM}${CL} \r"
|
|
|
|
sleep 1
|
|
|
|
clear
|
|
|
|
header_info
|
|
|
|
echo -e "${RD}Using Advanced Settings${CL}"
|
|
|
|
echo -e "${GN}Using CT Type ${BGN}$CT_TYPE1${CL}"
|
|
|
|
echo -e "${GN}Using CT Password ${BGN}$PW1${CL}"
|
|
|
|
echo -e "${GN}Using ID ${BGN}$CT_ID${CL}"
|
|
|
|
echo -e "${GN}Using CT Name ${BGN}$HN${CL}"
|
|
|
|
echo -e "${GN}Using Disk Size ${BGN}$SIZEDISK${CL}"
|
|
|
|
echo -e "${YW}Storages Available:${CL}"
|
|
|
|
echo " "
|
|
|
|
for stg in `pvesh get storage --noborder --noheader`
|
|
|
|
do
|
|
|
|
echo -e "${BL} - ${stg}${CL}"
|
|
|
|
done
|
|
|
|
echo " "
|
|
|
|
echo -e "${YW}Enter which storage to create the CT, or Press [ENTER] for Default: local-lvm "
|
|
|
|
read STORAGETYPE
|
|
|
|
if [ -z $STORAGETYPE ]; then STORAGETYPE="local-lvm"; fi;
|
|
|
|
echo -en "${GN}Set Storage To ${BL}$STORAGETYPE${CL}"
|
|
|
|
echo -e " ${CM}${CL} \r"
|
|
|
|
sleep 1
|
|
|
|
clear
|
|
|
|
header_info
|
|
|
|
echo -e "${RD}Using Advanced Settings${CL}"
|
|
|
|
echo -e "${GN}Using CT Type ${BGN}$CT_TYPE1${CL}"
|
|
|
|
echo -e "${GN}Using CT Password ${BGN}$PW1${CL}"
|
|
|
|
echo -e "${GN}Using ID ${BGN}$CT_ID${CL}"
|
|
|
|
echo -e "${GN}Using CT Name ${BGN}$HN${CL}"
|
|
|
|
echo -e "${GN}Using Disk Size ${BGN}$SIZEDISK${CL}"
|
|
|
|
echo -e "${GN}Using Storage ${BGN}$STORAGETYPE${CL}"
|
|
|
|
echo -e "${YW}Allocate CPU cores, or Press [ENTER] for Default: 2 "
|
|
|
|
read CORE_COUNT
|
|
|
|
if [ -z $CORE_COUNT ]; then CORE_COUNT="2"; fi;
|
|
|
|
echo -en "${GN}Set Cores To ${BL}$CORE_COUNT${CL}"
|
|
|
|
echo -e " ${CM}${CL} \r"
|
|
|
|
sleep 1
|
|
|
|
clear
|
|
|
|
header_info
|
|
|
|
echo -e "${RD}Using Advanced Settings${CL}"
|
|
|
|
echo -e "${GN}Using CT Type ${BGN}$CT_TYPE1${CL}"
|
|
|
|
echo -e "${GN}Using CT Password ${BGN}$PW1${CL}"
|
|
|
|
echo -e "${GN}Using ID ${BGN}$CT_ID${CL}"
|
|
|
|
echo -e "${GN}Using CT Name ${BGN}$HN${CL}"
|
|
|
|
echo -e "${GN}Using Disk Size ${BGN}$SIZEDISK${CL}"
|
|
|
|
echo -e "${GN}Using Storage ${BGN}$STORAGETYPE${CL}"
|
|
|
|
echo -e "${GN}Using ${BGN}${CORE_COUNT}vCPU${CL}"
|
|
|
|
echo -e "${YW}Allocate RAM in MiB, or Press [ENTER] for Default: 1024 "
|
|
|
|
read RAM_SIZE
|
|
|
|
if [ -z $RAM_SIZE ]; then RAM_SIZE="1024"; fi;
|
|
|
|
echo -en "${GN}Set RAM To ${BL}$RAM_SIZE${CL}"
|
|
|
|
echo -e " ${CM}${CL} \n"
|
|
|
|
sleep 1
|
|
|
|
clear
|
|
|
|
header_info
|
|
|
|
echo -e "${RD}Using Advanced Settings${CL}"
|
|
|
|
echo -e "${GN}Using CT Type ${BGN}$CT_TYPE1${CL}"
|
|
|
|
echo -e "${GN}Using CT Password ${BGN}$PW1${CL}"
|
|
|
|
echo -e "${GN}Using ID ${BGN}$CT_ID${CL}"
|
|
|
|
echo -e "${GN}Using CT Name ${BGN}$HN${CL}"
|
|
|
|
echo -e "${GN}Using Disk Size ${BGN}$SIZEDISK${CL}"
|
|
|
|
echo -e "${GN}Using Storage ${BGN}$STORAGETYPE${CL}"
|
|
|
|
echo -e "${GN}Using ${BGN}${CORE_COUNT}vCPU${CL}"
|
|
|
|
echo -e "${GN}Using ${BGN}${RAM_SIZE}MiB${CL}${GN} RAM${CL}"
|
|
|
|
echo -e "${YW}Enter a IP Address, or Press [ENTER] for Default: DHCP "
|
|
|
|
read NET
|
|
|
|
if [ -z $NET ]; then NET="dhcp"; fi;
|
|
|
|
echo -en "${GN}Set IP Address To ${BL}$NET${CL}"
|
|
|
|
echo -e " ${CM}${CL} \n"
|
|
|
|
sleep 1
|
|
|
|
clear
|
|
|
|
header_info
|
|
|
|
echo -e "${RD}Using Advanced Settings${CL}"
|
|
|
|
echo -e "${GN}Using CT Type ${BGN}$CT_TYPE1${CL}"
|
|
|
|
echo -e "${GN}Using CT Password ${BGN}$PW1${CL}"
|
|
|
|
echo -e "${GN}Using ID ${BGN}$CT_ID${CL}"
|
|
|
|
echo -e "${GN}Using CT Name ${BGN}$HN${CL}"
|
|
|
|
echo -e "${GN}Using Disk Size ${BGN}$SIZEDISK${CL}"
|
|
|
|
echo -e "${GN}Using Storage ${BGN}$STORAGETYPE${CL}"
|
|
|
|
echo -e "${GN}Using ${BGN}${CORE_COUNT}vCPU${CL}"
|
|
|
|
echo -e "${GN}Using ${BGN}${RAM_SIZE}MiB${CL}${GN} RAM${CL}"
|
|
|
|
echo -e "${GN}Using IP Address ${BGN}$NET${CL}"
|
|
|
|
echo -e "${YW}Enter a VLAN Tag, or Press [ENTER] for Default: NONE "
|
|
|
|
read VLAN1
|
|
|
|
if [ -z $VLAN1 ]; then VLAN1="NONE" VLAN=" ";
|
|
|
|
echo -en "${GN}Set VLAN Tag To ${BL}$VLAN1${CL}"
|
|
|
|
else
|
|
|
|
VLAN="-tag $VLAN1"
|
|
|
|
echo -en "${GN}Set VLAN Tag To ${BL}$VLAN1${CL}"
|
|
|
|
fi;
|
|
|
|
echo -e " ${CM}${CL} \n"
|
|
|
|
sleep 1
|
|
|
|
clear
|
|
|
|
header_info
|
|
|
|
echo -e "${RD}Using Advanced Settings${CL}"
|
|
|
|
echo -e "${GN}Using CT Type ${BGN}$CT_TYPE1${CL}"
|
|
|
|
echo -e "${GN}Using CT Password ${BGN}$PW1${CL}"
|
|
|
|
echo -e "${GN}Using ID ${BGN}$CT_ID${CL}"
|
|
|
|
echo -e "${GN}Using CT Name ${BGN}$HN${CL}"
|
|
|
|
echo -e "${GN}Using Disk Size ${BGN}$SIZEDISK${CL}"
|
|
|
|
echo -e "${GN}Using Storage ${BGN}$STORAGETYPE${CL}"
|
|
|
|
echo -e "${GN}Using ${BGN}${CORE_COUNT}vCPU${CL}"
|
|
|
|
echo -e "${GN}Using ${BGN}${RAM_SIZE}MiB${CL}${GN} RAM${CL}"
|
|
|
|
echo -e "${GN}Using IP Address ${BGN}$NET${CL}"
|
|
|
|
echo -e "${GN}Using VLAN Tag ${BGN}$VLAN1${CL}"
|
|
|
|
|
|
|
|
read -p "Are these settings correct(y/n)? " -n 1 -r
|
|
|
|
echo
|
|
|
|
if [[ ! $REPLY =~ ^[Yy]$ ]]
|
|
|
|
then
|
|
|
|
advanced_settings
|
|
|
|
fi
|
|
|
|
}
|
|
|
|
|
|
|
|
function start_script() {
|
|
|
|
echo -e "${YW}Type Advanced, or Press [ENTER] for Default Settings "
|
|
|
|
read SETTINGS
|
|
|
|
if [ -z $SETTINGS ]; then default_settings;
|
|
|
|
else
|
|
|
|
advanced_settings
|
|
|
|
fi;
|
|
|
|
}
|
2022-04-15 12:38:01 +00:00
|
|
|
pve_check
|
2022-04-15 11:49:24 +00:00
|
|
|
start_script
|
|
|
|
|
|
|
|
set -o errexit
|
|
|
|
set -o errtrace
|
|
|
|
set -o nounset
|
|
|
|
set -o pipefail
|
|
|
|
shopt -s expand_aliases
|
|
|
|
alias die='EXIT=$? LINE=$LINENO error_exit'
|
|
|
|
trap die ERR
|
|
|
|
trap cleanup EXIT
|
|
|
|
|
|
|
|
function error_exit() {
|
|
|
|
trap - ERR
|
|
|
|
local DEFAULT='Unknown failure occured.'
|
|
|
|
local REASON="\e[97m${1:-$DEFAULT}\e[39m"
|
|
|
|
local FLAG="\e[91m[ERROR] \e[93m$EXIT@$LINE"
|
|
|
|
msg "$FLAG $REASON"
|
|
|
|
[ ! -z ${CTID-} ] && cleanup_ctid
|
|
|
|
exit $EXIT
|
|
|
|
}
|
|
|
|
function warn() {
|
|
|
|
local REASON="\e[97m$1\e[39m"
|
|
|
|
local FLAG="\e[93m[WARNING]\e[39m"
|
|
|
|
msg "$FLAG $REASON"
|
|
|
|
}
|
|
|
|
function info() {
|
|
|
|
local REASON="$1"
|
|
|
|
local FLAG="\e[36m[INFO]\e[39m"
|
|
|
|
msg "$FLAG $REASON"
|
|
|
|
}
|
|
|
|
function msg() {
|
|
|
|
local TEXT="$1"
|
|
|
|
echo -e "$TEXT"
|
|
|
|
}
|
|
|
|
function cleanup_ctid() {
|
|
|
|
if $(pct status $CTID &>/dev/null); then
|
|
|
|
if [ "$(pct status $CTID | awk '{print $2}')" == "running" ]; then
|
|
|
|
pct stop $CTID
|
|
|
|
fi
|
|
|
|
pct destroy $CTID
|
|
|
|
elif [ "$(pvesm list $STORAGE --vmid $CTID)" != "" ]; then
|
|
|
|
pvesm free $ROOTFS
|
|
|
|
fi
|
|
|
|
}
|
|
|
|
function cleanup() {
|
|
|
|
popd >/dev/null
|
|
|
|
rm -rf $TEMP_DIR
|
|
|
|
}
|
2022-04-15 12:18:00 +00:00
|
|
|
if [ "$CT_TYPE" == "1" ]; then
|
2022-04-15 11:49:24 +00:00
|
|
|
FEATURES="nesting=1,keyctl=1"
|
|
|
|
else
|
|
|
|
FEATURES="nesting=1"
|
|
|
|
fi
|
|
|
|
|
|
|
|
TEMP_DIR=$(mktemp -d)
|
|
|
|
pushd $TEMP_DIR >/dev/null
|
|
|
|
|
|
|
|
export CTID=$CT_ID
|
|
|
|
export PCT_OSTYPE=debian
|
|
|
|
export PCT_OSVERSION=11
|
|
|
|
export PCT_DISK_SIZE=$SIZEDISK
|
|
|
|
export PCT_OPTIONS="
|
|
|
|
-features $FEATURES
|
|
|
|
-hostname $HN
|
|
|
|
-net0 name=eth0,bridge=vmbr0,ip=$NET
|
|
|
|
$VLAN
|
|
|
|
-onboot 1
|
|
|
|
-cores $CORE_COUNT
|
|
|
|
-memory $RAM_SIZE
|
|
|
|
-unprivileged $CT_TYPE
|
|
|
|
$PW
|
|
|
|
"
|
|
|
|
bash -c "$(wget -qLO - https://raw.githubusercontent.com/tteck/Proxmox/main/ct/create_lxc.sh)" || exit
|
|
|
|
|
|
|
|
STORAGE_TYPE=$(pvesm status -storage $(pct config $CTID | grep rootfs | awk -F ":" '{print $2}') | awk 'NR>1 {print $2}')
|
|
|
|
if [ "$STORAGE_TYPE" == "zfspool" ]; then
|
|
|
|
warn "Some addons may not work due to ZFS not supporting 'fallocate'."
|
|
|
|
fi
|
|
|
|
|
|
|
|
LXC_CONFIG=/etc/pve/lxc/${CTID}.conf
|
|
|
|
cat <<EOF >> $LXC_CONFIG
|
|
|
|
lxc.cgroup2.devices.allow: a
|
|
|
|
lxc.cap.drop:
|
|
|
|
lxc.cgroup2.devices.allow: c 188:* rwm
|
|
|
|
lxc.cgroup2.devices.allow: c 189:* rwm
|
|
|
|
lxc.mount.entry: /dev/serial/by-id dev/serial/by-id none bind,optional,create=dir
|
|
|
|
lxc.mount.entry: /dev/ttyUSB0 dev/ttyUSB0 none bind,optional,create=file
|
|
|
|
lxc.mount.entry: /dev/ttyACM0 dev/ttyACM0 none bind,optional,create=file
|
|
|
|
EOF
|
|
|
|
|
|
|
|
echo -en "${GN} Starting LXC Container... "
|
|
|
|
pct start $CTID
|
|
|
|
echo -e "${CM}${CL} \r"
|
|
|
|
|
|
|
|
alias lxc-cmd="lxc-attach -n $CTID --"
|
|
|
|
|
|
|
|
lxc-cmd bash -c "$(wget -qLO - https://raw.githubusercontent.com/tteck/Proxmox/main/setup/zigbee2mqtt-install.sh)" || exit
|
|
|
|
|
|
|
|
IP=$(pct exec $CTID ip a s dev eth0 | sed -n '/inet / s/\// /p' | awk '{print $2}')
|
|
|
|
|
|
|
|
echo -e "${GN}Successfully created ${APP} LXC to${CL} ${BL}$CTID${CL}. \n"
|